The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria

Haier split systems: top 10 best models + tips for choosing climate technology

LG p07ep

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria

The Chinese company LG has released an ultra new air conditioning system. Inverter technology saves up to 60 percent of energy.

The conditioner is equipped with protective barriers which interfere with reproduction of bacteria after performance of work. In addition, the manufacturer has included the Jet Cool function in the device, with the help of which the room is cooled within five minutes. The p07ep significantly reduces the number of "dead zones" in the room.

Type of inverter
Mode Dehumidification, ventilation, cooling, heating
Power 650 W
Price 19700

pros

  • Doesn't make noise.
  • Smartphone control.

Minuses

The presence of a sour smell during air purification.

LG p07ep

Advantages of a split system

Why did it have to be so complicated? Indeed, in a monoblock, all these elements get along perfectly in a single case.This arrangement gives the split system a number of advantages:

Saving space in the room is one of the main advantages of split systems. The compressor block occupies a fairly large volume, but it occupies it in another room or even on the street. True, for work in the winter period, you will have to take care of additional equipment - the so-called "winter kit", with which the compressor is not afraid of even 30-40-degree frosts.

Lots of installation options. The ability to separate two split system units at a considerable distance from each other (but not more than 15-20 meters) opens up many layout options. For example, you can completely turn a utility room into a cold store by sheathing the walls with sandwich panels. It remains only to make a small hole in the wall for the cable and copper pipes, and then install the compressor outside and the fan unit inside.

The ability to bring noise and heat out. Even the most expensive and high-quality compressor makes noise during operation. And this is not very conducive to creating the right working atmosphere in the kitchen. And if you have a quiet cozy place, then the compressor rumble will reach the dining room. The output of the "noisy" part of the street - an excellent solution to this problem. Similarly, with the excessive heat that this block emits.

It should be noted that the installation of a split system is a rather complicated and time-consuming process. You will have to make various holes and recesses in the walls. In addition, a drainage sewer supply will be required to drain the condensate.

Refrigeration units manufactured by Polair (Polair, Russia)

Monoblock / Split Polair 109 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10 25 1117 9,8
30 1059 9,0
35 1000 8,4
40 939 7,6
+5 25 966 8,0
30 912 7,3
35 858 6,6
40 802 6,1
25 828 6,4
30 779 5,9
35 728 5,3
40 677 4,8
-5 25 704 5,0
30 659 4,5
35 612 4,1
40 564 3,6
-10 * 25 603 4,0
30 560 3,6
35 516 3,1
40 471 2,9

Monoblock / Split Polair 111 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25 1296 12,1
30 1229 11,3
35 1159 10,4
40 1087 9,4
+5  25 1133 10,0
30 1070 9,3
35 1006 8,5
40 939 7,6
25 983 8,1
30 924 7,4
35 864 6,6
40 802 6,1
-5  25 847 6,5
30 792 6,0
35 736 5,4
40 677 4,8
-10 * 25 729 5,3
30 677 4,8
35 624 4,1
40 569 3,6

Monoblock / Split Polair 113 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25 1579 16,3
30 1497 15,0
35 1412 13,9
40 1324 12,5
+5  25 1396 13,6
30 1318 12,5
35 1238 11,4
40 1156 10,3
25 1225 11,1
30 1152 10,3
35 1076 9,3
40 998 8,4
-5  25 1070 9,3
30 1000 8,4
35 928 7,4
40 854 6,6
-10 * 25 933 7,5
30 867 6,8
35 797 6,0
40 725 5,3

Monoblock / Split Polair 115 S

chamber temperature, °C ambient temperature, °C Q, W

V, m3

+10  25 1744 18,5
30 1651 17,3
35 1556 15,9
40 1457 14,5
+5  25 1551 15,9
30 1464 14,6
35 1374 13,3
40 1280 11,9
25 1370 13,3
30 1287 12,0
35 1202 10,9
40 1113 9,8
-5  25 1197 10,8
30 1120 9,9
35 1039 8,9
40 954 7,8
-10 * 25 1050 9,0
30 976 8,1
35 898 7,0
40 816 6,3

Monoblock / Split Polair 218 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25

2175

24,1

30

2067

22,6

35

1955

21,3

40

1840

19,8

+5

25

1926

20,9

30

1825

19,6

35

1720

18,1

40

1612

16,6

25

1693

17,8

30

1598

16,5

35

1499

15,1

40

1398

13,6

-5

25

1475

14,8

30

1386

13,5

35

1293

12,1

40

1198

10,8

-10 *

25

1281

11,9

30

1197

10,8

35

1109

9,8

40

1018

8,6

Monoblock / Split Polair 222 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25 2605 30,9
30 2485 28,9
35 2357 26,8
40 2223 24,8
+5  25 2292 25,8
30 2183 24,1
35 2065 22,6
40 1940 21,1
25 1987 21,6
30 1888 20,4
35 1781 19,0
40 1667 17,5
-5  25 1684 17,6
30 1596 16,5
35 1500 15,1
40 1396 13,6
-10 * 25 1404 13,8
30 1329 12,6
35 1244 11,4
40 1150 10,3

Monoblock / Split Polair 226 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25 3017 38,1
30 2870 35,5
35 2715 32,9
40 2553 30,0
+5  25 2700 32,5
30 2561 30,1
35 2415 27,6
40 2261 25,3
25 2395 27,4
30 2265 25,4
35 2126 23,4
40 1980 21,6
-5  25 2107 23,1
30 1985 21,6
35 1853 20,0
40 1714 18,1
-10 * 25 1837 19,8
30 1723 18,3
35 1598 16,5
40 1465 14,6

Monoblock / Split Polair 232 S

chamber temperature, °C ambient temperature, °C Q, W V, m3
+10  25 3740 51,0
30 3600 48,5
35 3482 46,4
+5  25 3381 44,6
30 3242 42,1
35 3110 39,8
40 3026 38,3
25 3027 38,4
30 2895 36,0
35 2755 33,3
40 2646 31,6
-5  25 2680 32,3
30 2559 30,1
35 2417 27,8
40 2290 25,8
-10 * 25 2338 26,5
30 2233 24,8
35 2094 23,0
40 1956 21,3
Read also:  When is the best time to drill a well?

* — in a special version (upon request)

Design

The most popular type of air coolers are finned tubular models. Inside this device there are tubes inside which the refrigerant circulates. The fan directs the air flow so that it passes through the accumulation of these tubes. Upon contact with the cooled elements, the air masses lower their temperature, and a cool air stream is obtained at the outlet of the installation.

For more efficient cooling, engineers strive to maximize the area of ​​​​contact of the cooled air with the refrigerant. To do this, the tubes are equipped with fins made of heat-conducting material. With this design, the air comes into contact with the cooling elements in a larger space, which allows much faster cooling.

Tubes and ribs are attached inside the frame. This design is mounted inside the ventilation and with the help of fans it pumps cool air into the room.

Household appliances are not built into ventilation systems, they remain mobile and can be moved between rooms. These units produce cooling by taking air masses from the room and passing them through a grid of refrigerant tubes.

Hisense as-07hr4syddh

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria

The Chinese-made non-inverter air conditioner is a powerful temperature control apparatus. The device not only regulates the air temperature, but also cleans the air thanks to built-in filters.

The wall-mounted model has an indication of the operating mode. The case of the conditioner is made of quality plastic. The device has built-in many modes that allow you to choose the optimal temperature for a person.

Type of Non-inverter
Service area 20 m2
Temperature range 16-30 degrees
Price 14790

pros

  • Lots of modes.
  • Built-in filtering.

Minuses

Noise.

Hisense as-07hr4syddh

About the benefits and dangers of hydrogen water, the features of choosing a clothes dryer, an electric built-in panel, you can get acquainted with the rating of the best air conditioners for an apartment and the best floor fans on the site.

The best manufacturers of refrigeration split systems

Today, manufacturers offer just a huge range of air conditioners. Such a variety creates a lot of inconvenience for an unprepared buyer. Partially solve the problem by narrowing the search circle to devices only from the most reliable and trusted suppliers.

Brand #1 - Polus

If you need to order an inexpensive refrigeration split system, then choose the Polus brand. These are relatively cheap units that show good power, and their service life is calculated in decades.

Read also:  Treatment of cracks in concrete - injection

Polus engineers paid particular attention to ease of maintenance. Almost all air conditioners of this brand have an easily removable panel.

It provides full access to all internal components and systems of the unit

Brand #2 - Polar

Polair offers refrigeration air conditioners in two lines: Professionale and Standard. As is clear from the names, the first class is designed for industrial enterprises with huge storage facilities.

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteriaSplit systems Standard are perfect for small shops and catering establishments. Often chosen by small business owners

The features of Polaris devices are as follows:

  • High build quality. The manufacturer uses only first-class stainless steel, aluminum, and connecting tubes are made exclusively of copper.
  • Simplicity. Understand how to change the temperature regime everyone can. Split systems have elementary control and are often equipped with a remote control panel.
  • Noiselessness. The entire "noisy" part of the air conditioner can be taken out into the street. As a result, it will be comfortable to be in the room.

As for the shortcomings of devices from this supplier, the restriction on the installation site is confusing. So, the distance between the outdoor and indoor units cannot be more than 5 meters.

It is also better to entrust the installation to experienced craftsmen. After all, Polair split systems usually have a complex design. Therefore, the installation itself will not work.

Brand #3 - Ariada

Ariada stands out from the competition with a wide range of low and medium temperature devices. That being said, the price of most air conditioners is more than affordable, making them a great choice for everyone.

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria
Refrigeration split-systems from "Ariada" will cope with the freezing of products, cooling, as well as maintaining the set temperature. At the same time, the high quality of the materials used guarantees a long and trouble-free service.

The list of manufacturer's advantages should be supplemented by the fact that engineers use modern technologies in the production of blocks and components. Each model is also thoroughly tested.

Principal differences between refrigeration split systems

Such split systems consist of two blocks. The outdoor unit is placed outside the chamber. It can be located up to 50 meters away from the indoor unit, usually attached to the wall.

The indoor unit is placed inside the chamber. The blocks are connected by copper tubes, and their connection is provided by a power cable. You can read more about installing split systems in this material.

Also on the market you can find a number of models of refrigeration units that are paired with two or more compressors. Due to their reliability, these devices are ideal for production. After all, if one compressor fails, then others can take over its functions.

Unlike air conditioners of other classes, refrigeration units are characterized by high performance and relatively low energy consumption.

To do this, they are equipped with automatic reset switches as well as an elaborate refrigerant capillary system.

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria
The device is controlled by the built-in monitor. It supports the coordinated work of all systems and electrical components located inside the refrigeration split system.

Another important advantage of the air conditioners presented above is their protection from environmental influences and sudden voltage drops.Most models have a built-in system that protects them from exposure to high or low pressure.

Significantly extends the life of the split system, the presence of an automatic defrosting function. As a result, the housing, as well as all the components of the outdoor and indoor units, are reliably protected from the negative effects of ice.

In addition to separate (split) systems, refrigeration monoblocks are popular. This is a fully equipped device that is installed on the wall of the chamber.

It consists of two parts, identical to the split system, but both parts are interconnected into one device, in a single housing.

This important difference gives them a great advantage, as it allows them to be placed in cold rooms where other units simply do not fit in height or wall thickness. The rest of the features of the two options are almost the same.

Split system selection options

Before buying a domestic air conditioner, you should compare its characteristics with the upcoming operating conditions.

It is important to determine the location of its location and the necessary functionality.

The main selection criteria include:

  • constructive execution;
  • compressor type;
  • power;
  • noise level;
  • operating modes.

Also important when choosing is additional functionality, which, on the one hand, adds comfort during the operation of the equipment. On the other hand, the price tag of equipment increases significantly

Preferred system type

Based on the device, wall, window, mobile, cassette, channel splits and multi-systems are distinguished.

In everyday life, wall-mounted air conditioners are most in demand. These are traditional two-block split systems.Their advantages: affordability, compactness, quiet operation

Read also:  Pros and cons of a humidifier for a child: a real assessment of use

Features of other options for climate technology:

  1. Window. Easy to install, but partially block the flow of daylight. In addition, they are distinguished by more noisy operation, insufficient power for spacious rooms, limited use of curtains.
  2. Mobile. Compactness and the ability to move from one room to another are the main arguments in favor of such splits. Cons: low power, noisy, the need to equip holes to remove warm air.
  3. Cassette. Differ in high productivity, the hidden installation. Installation is carried out in the subceiling space, which is not always possible.
  4. Channel. The installation method is similar to cassette splits, but here one unit serves several rooms. This option is suitable for private homes, offices.
  5. Multi-systems. A complex of equipment from one outdoor unit and several indoor modules. The system is used if it is not possible to install an air conditioner in each room. Cons: complexity and high cost of installation.

The main disadvantage of the last three models is the complexity of installation. It is better to entrust all installation work to a specialist. And with the installation of the first three varieties, you can handle it yourself. Read on for how to do this.

Compressor type and equipment power

Split systems are equipped with a rotary or inverter compressor. The first type works according to the scheme: turning on, reaching the set temperature, turning off. Start-up cycling increases the load on the unit and the power grid.

The inverter compressor operates at different speeds, adjusting to the room temperature. Pros: quiet running, long service life, reduced energy consumption.

We talked in more detail about the principles of operation of inverter and conventional split systems in this material.

When choosing the power of the air conditioner, you must follow the rule: 1 kW per 10 square meters. m. The norm is relevant for rooms with ceilings up to 3 meters

Determining the required power of the air conditioner by the area of ​​​​the room, it is desirable to increase the indicator by a quarter in the following cases:

  • the location of the room on the south side;
  • an abundance of technology;
  • residence of a large number of people.

The comfort of use is affected by the noise emitted by the indoor unit. The average sound indicator is 32-33 dB, which is comparable to a whisper.

Main and additional functions

It is desirable that the split could function in the following modes:

  • turbo - fast heating, cooling;
  • night - silent operation at reduced speeds;
  • timer - the ability to select the start or shutdown time;
  • auto - equipment adjusts the intensity of work to the microclimate.

Additional, practical functions include self-diagnosis of problems. The unit with the help of light and sound indication will tell the user in which area the failure occurred.

A handy feature is the motion sensor. The air conditioner switches to standby mode when activity decreases - this contributes to economical energy consumption

It is advisable to provide a system against the accumulation of ice on the outdoor unit

This is especially important if the air conditioner is planned to be used in winter to heat the air.

ballu bse-09hn1

The list of the best is headed by a modern two-component system with the Combo2 function.This is filtration with the addition of catechin, vitamins C and ozone-safe freon R410. These components allow you to purify the air through circulation.

The technique has an advantage that distinguishes it from other similar ones: micro-adjustment of temperature without sudden transitions significantly reduces energy consumption by 30-35%. The Bse-09hn1 model is equipped with an auto-restart, which helps to set the time and mode of operation in advance.The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria

Service area 29 m2
Mode Ventilation, cooling, heating
Airflow 8 cpm
Price 14500

pros

  • Quality build.
  • Beautiful design.

Minuses

No.

ballu bse-09hn1

In conclusion about industrial premises

The above aggregated calculation is not suitable for industrial buildings due to the inconsistency specific thermal characteristic q different types of building structures. Although the methodology proposed by SNiP is also based on the summation of all heat inputs.

The algorithm for determining the refrigeration capacity for air conditioning a production facility looks like this:

  1. Determine the amount of heat flow through external enclosures by calculating the thermal resistance of the walls, roof and floor. The methodology is described in detail in the publication on the calculation of the heat load on heating - from the point of view of heat engineering, there is no difference.
  2. Find out the number of personnel, calculate heat generation from office equipment and people depending on the intensity of work.
  3. Sum up the heat output of all electric motors and other equipment, taking into account the simultaneity and frequency of switching on.
  4. If hot technological tanks, furnaces or parts are located in the workshops, it will be necessary to determine the amount of heat flow from heated surfaces.
  5. Find out the amount of supply air supplied by ventilation units, calculate the energy consumption for its cooling.

The air conditioning of some industrial premises (server rooms, large offices, cafes) is easier to calculate - there are less heat gains. The master installer will tell about this technique in his video.

The best Polair split systems: TOP-7 refrigeration systems + equipment selection criteria

Rating
Website about plumbing

We advise you to read

Where to fill the powder in the washing machine and how much powder to pour